Product Tags: PULSE OXIMETER, بلس اوكزيميتر, بلس اوكسيمير, بلص, بلص اوكزيميتر, بلص اوكسيمير, جهاز البلس, جهاز البلص, جهاز بلس اوكزيميتر, جهاز بلس اوكسيميتر, جهاز بلص اوكزيميتر, جهاز بلص اوكسيميتر, جهاز قياس اوكسجين الدم, جهاز قياس نسبة اوكسجين الدم, جهاز قياس نسبه اوكسجين الدم, قياس اوكسجين الدم, قياس نسبة اوكسجين الدم, قياس نسبه اوكسجين الدم, مقياس اوكسجين الدم, مقياس نسبة اوكسجين الدم, مقياس نسبه اوكسجين الدم
Product Page: https://abulailcenter.com/product/vascular-doppler-with-8-mhz-vessel-crooked-probe-cd8-0-ipx4-contecvd/
Brand:
Product DescriptionVascular Doppler
with 8 Mhz Vessel Crooked Probe | Contec
Pocket Doppler vascular Sonoline C with 8Mhz
Doppler Vascular Contec Sonoline C1
High-quality Material
Accurate Measurement
Intelligent
Low Noise
- This device is ideal for vascular examinations in the wards/clinics.
- Ideal for evaluating vascular insufficiency.
- Ideal for diabetes care or diabetes clinics.
- The 8 MHz waterproof probe is connected to the handheld Doppler device via a USB port.
- The probe is compatible with all Contec handheld pocket doppler devices.
It is equipped with a mini USB plug and is compatible with Pocket Doppler machines.
- This probe is used for a vascular peripheral examination by doctors/sonographers and will most likely not be used by patients themselves.
Note: The Doppler device used is the same as the fetal Doppler device,
but with a different, 8 MHz, doppler probe.
What is a Vascular Doppler device?
- A vascular Doppler device is a medical diagnostic tool used to evaluate blood flow.
- It uses ultrasound waves to detect the speed (and in certain cases direction) of blood flow through blood vessels.
Vascular Doppler devices are commonly used to:
Assess blood flow in arteries and veins:
- The device can help identify blockages or obstructions in blood vessels that may be causing poor blood flow or reduced circulation.
Monitor blood flow during surgery:
- Surgeons may use a Doppler device to monitor blood flow during procedures such as bypass surgery, angioplasty, or endarterectomy.
Diagnose conditions affecting blood flow:
A vascular Doppler (such as this portable or pocket Doppler device) may be used to diagnose conditions such as:
- Peripheral Arterial Disease (PAD)
- Deep Vein Thrombosis (DVT)
- Varicose Veins, such as in certain diabetic conditions.
Overall, the vascular Doppler is a non-invasive, safe, and effective way to evaluate blood flow and diagnose conditions that affect circulation.
Features
1) Compact Design
- Delicate and compact design, portable and easy to use
2) Crooked Probe Structure
- which is easy to operate and increases the feeling of comfort, embodies the humanized design.
3) 3 working Modes
- Real-time HR Display Mode
- Averaged HR Display Mode
- Manual Mode
4) High precision
5) Probe falls off detection
- Battery status indication
6) Pluggable USB probe interface
- The probe can be replaced
7) Automatic shutdown
- The device will automatically turn off if there is no signal within 1 minute
8) Audio interface
- Can be connected to other recording devices by recording cable
- Record sounds in real-time
9) Two 1.5V batteries (AA LR6)
- can last more than 8 hours for normal use
Performance
- 1) Safety classification:
internally powered equipment, type CF applied part
- 2) Display:
3.8 × 3.2 cm LCD screen
- 3) Range of heart rate:
50~240 BPM (BPM: beats per minute)
- 4) Resolution: 1 BPM
- 5) Accuracy: ± 2 BPM
- 6) Power consumption: <1 W
- 7) Rated operational voltage: DC3 V
- 8) Battery: two 1.5V batteries (type: AA LR6)
Probe
- 1) Nominal Frequency: 3.0 MHz
- 2) Working Frequency: 3.0 MHz ± 10%
- 3) Maximum Output Sensitivity: ≥90 dB
- 4) Ultrasonic Output Power: P<20 mW
- 5) Negative Peak Sound Pressure: P_< 1 MPa
- 6) Output Beam Intensity: Iob<20 mW/cm2
- 7) Spatial-peak Temporal-average Derived Intensity: Ispta<100 mW/cm2
- 8) Working Mode: Continuous Wave Doppler
- 9) Effective Radiating Area of Transducer: < 157 mm2
Physical characteristic
- Dimension: 13.5 (L) × 9.2 (W) × 2.9 cm(H)
- Weight: about 245 g (with battery)
Accessories
- 1) User manual (1 pc)
- 2) 8 Mhz Vessel crooked probe (1 pc)
Product Attributes
- Dimensions: 13.5 × 9.2 × 2.9 cm
- Weight: 0.25 kg
|