Fundamental Theories
1. Acupuncture, Moxibustion, and Massage:
The pulse wave of the apparatus, after being set up and adjusted, functions as countless electrical
needles to simulate the treatments of acupuncture, moxibustion, and massage, conducting along
the meridians and collaterals to the relevant viscera and along the sensory nerves to the central
nervous system.
2. Medical Lotion Introduction Technology:
Applying the introducing function of this treatment apparatus with the combination of traditional
Chinese medicine (medical liquor) such as the alcoholic pro arthritis and traumatic, etc, the
medical lotion can be osmotically “introduced” to the pathological human tissue.
3. Sleeping:
The design of the apparatus that digital circuit changes into an analog circuit (computer chipsets
the electrical pulse suitable for sleeping) applies to simulate the electrical needle stimulation on the
relevant acupuncture points, thus arousing the passive excitement of the parasympathetic nerves
distributing in the head, counter-dominating the motor nerves to relief the stimulation felt, reducing
the nervous function respondent to stress (tranquilization) and ultimately relaxing the psychic pressure
(nerves), provoking the drowsiness (tranquilization) and inducing to the sleeping status (The specific mechanism would be described elsewhere).
Performance Characteristics:
- High-tech design of digital circuit changing into an analog circuit makes the stable
product performance. - The new self-felling mode leads to the comfort during treatment.
- The output spectrum is continually adjustable and the output power is large.
- Convenient design and simple operation so it can be known how to operate
immediately after reading the instruction. - It, economical, safe, and dependable, applies alternating current power supply so
the treatment can be conducted at any moment.
Waveforms:
- IFC – Interferential Current
- TENS – Alternating
- NMS – Burst
- Galvanic Interrupted
Main Structure
It is constituted with the main unit, skin electrode (electroconductive rubber), belt, cable.
Treatment apparatus model, fittings, and power.
Main performance and technological index
No | Model Specification | Model: EM-F38 |
1 | Power supply and Voltage | a.c. 220V±22V, 50Hz±1Hz net power supply direct supply |
2 | Power | ≤28 VA |
3 | Frequency range | 0.5 – 5000 Hz |
4 | Pulse duration | 0.07 – 1.2 ms |
5 | Single electrode max output energy | <300 MJ |
6 | Single electrode output effective voltage | <25 V |
7 | Fuse | ⌽ 5X20mm F1A250V Notes: installed inside the apparatus, don’t disassemble at will! |
8 | Output pulse feature curve | B mode linear continually adjustable V out min < V out max 2% (v) |
9 | Time setting | Six grades for 5, 10, 15, 20, 25, 30 min |
10 | Environmental requirement for apparatus application | |
<1> operation | Environmental temperature range 5 ~40°C
Relative temperature range ≤ 80% Atmospheric pressure range: 86~106 KPa |
|
11 | <2> transportation and storage | Environmental temperature range: -50 ~55°C
Relative temperature range ≤ 93% Atmospheric pressure range: 50 ~106 KPa |
12 | Dimensions (main unit) | 23 X 16.5 x 6.5 cm |
13 | Weight | 1.5 kg |
14 | Electrode pad size | ⌽ 97 mmHg |
Include:
- Main unit: 1 unit
- Belt: 4 pcs
- Electrode cable 4 pcs
- Electrode pad 8 pcs
- Usage Instruction Index 1 pcs